• CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
  • CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor

CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor

  • Brand: CONTEC
  • Availability: In Stock
  • Our Price:$289.99

  • 8th Anniversary Promotion Price:$275.49

- +

Guaranty: 12 Months Warranty

Shipping: Free Shipping Over $49!

CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor

CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
1.Introduction
Capnograph adopts sidestream method to measure the end-tidal carbon dioxide, airway respiration rate and other parameters. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow as well as indirectly reflect the alveolar ventilation standard. Meanwhile, it can also detect the blood oxygen saturation and pulse.
 
2.Features
1)End-tidal CO2 measurement function
2)Respiration rate measurement function
3)SpO2 measurement function
4)Pulse rate measurement function
5)Over-limit alarm function for EtCO2、Respiration rate,SpO2 and Pulse rate
6)Low battery alarm function
 
3.Performance
-->End-tidal CO2 measurement:
1)Measurement range: 0 ~150mmHg
2)Resolution: 1mmHg
3)Accuracy:
0~40 mmHg:±2 mmHg
41~70 mmHg:±5% of readings
71~100 mmHg:±8% of readings
101~150 mmHg:±10% of readings
 
-->Respiration rate measurement:
1)Measurement range: 2rpm~120rbpm
2)Resolution: 1rpm
3)Accuracy: ±1rpm
 
-->SpO2 measurement:
1)Measurement range: 30~100 %
2)Resolution: 1%
3)Accuracy: 
               70~100 %:2 %
               0 ~ 69 %:undefinition
 
-->Pulse rate measurement:
1)Measurement range: 25~250 bpm
2)Resolution: 1bpm
3)Accuracy: ±2 bpm or ±2%,whichever is greater
 
4.Safety characteristic:
1)Device type: internally powered equipment
2)Degree of protection against electric shock: type BF applied part
3)Degree of protection against ingress of liquid: IPX1
 
5.Accessories
User Manual
Blood oxygen probe
Sampling pipe
 
6.Physical Characteristic
Dimension: 159*72*31 mm
Weight: 270 g
Working environment
Temperature: 5℃~40℃
Relative humidity: 30%~ 75%, no condensation
Atmospheric pressure: 700hPa~1060hPa
Power supply: DC 3.7V (rechargeable lithium battries)
Input power: ≤1.5VA
 
7.Selling points analysis
  1.2.8'' color LCD screen, user-friendly interface, easy to operate
  2.Compact and portable design
  3.Visual and audible alarm system
  4.Alarm limits and unit can be set
  5.With automatic compensation of atmospheric pressure
  6.Suitable for use in medical transfer, emergency, surgery, monitoring and other situations
 
CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
 
CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
 
CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
 
CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
 
CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
 
CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
 
CONTEC CA10S ETCO2 Capnograph Respiration Rate End-tidal CO2 Monitor
Prev:  UTMD uPM60VCM Handheld Veterinary Capnography Monitor - SPO2 PR RESP ETCO2(mainstream)
Next: Sonostar V6 Portable B/W Veterinary Ultrasound Scanner Ultrasound Diagnostic System IP65 Waterproof

There are no reviews for this product.

Write a review

captcha
Note: HTML is not translated!
            

Related Products